| Type | Art. no. | Max. load [daN] | Diameter D [mm] | Height H [mm] | Bottom pad | |
---|
| PRG 85 /405 | 1.16085.43 | 450 | 85 | 19.5 | 405 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Extremely stable. Best suited for light machines and systems for which there is permanently defined ground contact.
| Type | PRG 85 /405 | Name | Jacmounts pat. | Art. no. | 1.16085.43 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 450 | Weight [kg] | 0.31 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 19.5 | Height Hmin [mm] M10 | 44 | Height Hmin [mm] M12 | 44.5 | Height Hmin [mm] M16 | 52 | Diameter D [mm] | 85 |
Pad equipment |
---|
Bottom pad type | 405 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 44 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G1 | M10, M12, M16 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 85 /705 | 1.16085.58 | 900 | 85 | 19.5 | 705 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Application secure thanks to high level of damping. Very good stability due to high ground adhesion. | Type | PRG 85 /705 | Name | Jacmounts pat. | Art. no. | 1.16085.58 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 900 | Weight [kg] | 0.316 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height H [mm] | 19.5 | Height Hmin [mm] M10 | 44 | Height Hmin [mm] M12 | 44.5 | Height Hmin [mm] M16 | 52 | Diameter D [mm] | 85 |
Pad equipment |
---|
Bottom pad type | 705 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 44 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G1 | M10, M12, M16 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 85 /905 | 1.16085.73 | 1400 | 85 | 19.5 | 905 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For applications with high static load. Excellent leveling stability and high overall stability. Very economical.
| Type | PRG 85 /905 | Name | Jacmounts pat. | Art. no. | 1.16085.73 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 1400 | Weight [kg] | 0.32 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 19.5 | Height Hmin [mm] M10 | 44 | Height Hmin [mm] M12 | 44.5 | Height Hmin [mm] M16 | 52 | Diameter D [mm] | 85 |
Pad equipment |
---|
Bottom pad type | 905 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 44 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G1 | M10, M12, M16 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 125 /405 | 1.16125.43 | 1000 | 125 | 24.5 | 405 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Extremely stable. Best suited for light machines and systems for which there is permanently defined ground contact.
| Type | PRG 125 /405 | Name | Jacmounts pat. | Art. no. | 1.16125.43 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 1000 | Weight [kg] | 0.871 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 24.5 | Height Hmin [mm] M16 | 52 | Height Hmin [mm] M20 | 63 | Height Hmin [mm] M24 | 73.5 | Diameter D [mm] | 125 |
Pad equipment |
---|
Bottom pad type | 405 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 104 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRG 125 /705 | 1.16125.58 | 2000 | 125 | 24.5 | 705 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Application secure thanks to high level of damping. Very good stability due to high ground adhesion. | Type | PRG 125 /705 | Name | Jacmounts pat. | Art. no. | 1.16125.58 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 2000 | Weight [kg] | 0.854 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height H [mm] | 24.5 | Height Hmin [mm] M16 | 52 | Height Hmin [mm] M20 | 63 | Height Hmin [mm] M24 | 73.5 | Diameter D [mm] | 125 |
Pad equipment |
---|
Bottom pad type | 705 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 104 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRG 125 /905 | 1.16125.73 | 3000 | 125 | 24.5 | 905 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For applications with high static load. Excellent leveling stability and high overall stability. Very economical.
| Type | PRG 125 /905 | Name | Jacmounts pat. | Art. no. | 1.16125.73 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 3000 | Weight [kg] | 0.86 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 24.5 | Height Hmin [mm] M16 | 52 | Height Hmin [mm] M20 | 63 | Height Hmin [mm] M24 | 73.5 | Diameter D [mm] | 125 |
Pad equipment |
---|
Bottom pad type | 905 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 104 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRG 170 /405 | 1.16170.43 | 2000 | 170 | 25 | 405 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Extremely stable. Best suited for light machines and systems for which there is permanently defined ground contact.
| Type | PRG 170 /405 | Name | Jacmounts pat. | Art. no. | 1.16170.43 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 2000 | Weight [kg] | 1.7 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 25 | Height Hmin [mm] M16 | 52.5 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 170 |
Pad equipment |
---|
Bottom pad type | 405 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 201 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 170 /705 | 1.16170.58 | 4000 | 170 | 25 | 705 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Application secure thanks to high level of damping. Very good stability due to high ground adhesion. | Type | PRG 170 /705 | Name | Jacmounts pat. | Art. no. | 1.16170.58 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 4000 | Weight [kg] | 1.697 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height H [mm] | 25 | Height Hmin [mm] M16 | 52.5 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 170 |
Pad equipment |
---|
Bottom pad type | 705 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 201 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 170 /905 | 1.16170.73 | 4500 | 170 | 25 | 905 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For applications with high static load. Excellent leveling stability and high overall stability. Very economical.
| Type | PRG 170 /905 | Name | Jacmounts pat. | Art. no. | 1.16170.73 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 4500 | Weight [kg] | 1.65 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 25 | Height Hmin [mm] M16 | 52.5 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 170 |
Pad equipment |
---|
Bottom pad type | 905 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 201 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 230 /405 | 1.16230.43 | 3500 | 230 | 27 | 405 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Extremely stable. Best suited for light machines and systems for which there is permanently defined ground contact.
| Type | PRG 230 /405 | Name | Jacmounts pat. | Art. no. | 1.16230.43 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 3500 | Weight [kg] | 4.07 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 27 | Height Hmin [mm] M16 | 53 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 230 |
Pad equipment |
---|
Bottom pad type | 405 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 380 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 230 /705 | 1.16230.58 | 6000 | 230 | 27 | 705 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
Application secure thanks to high level of damping. Very good stability due to high ground adhesion. | Type | PRG 230 /705 | Name | Jacmounts pat. | Art. no. | 1.16230.58 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 6000 | Weight [kg] | 4.2 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height H [mm] | 27 | Height Hmin [mm] M16 | 53 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 230 |
Pad equipment |
---|
Bottom pad type | 705 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 380 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRG 230 /905 | 1.16230.73 | 6000 | 230 | 27 | 905 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For applications with high static load. Excellent leveling stability and high overall stability. Very economical.
| Type | PRG 230 /905 | Name | Jacmounts pat. | Art. no. | 1.16230.73 | Color | RAL 7001 silver grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 6000 | Weight [kg] | 4.186 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height H [mm] | 27 | Height Hmin [mm] M16 | 53 | Height Hmin [mm] M20 | 63.5 | Height Hmin [mm] M24 | 74.5 | Diameter D [mm] | 230 |
Pad equipment |
---|
Bottom pad type | 905 | Pad thickness unloaded [mm] | 5 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 380 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Special studs G2 | M16, M20, M24 | more |
Useful remarks |
---|
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. |
Remark extent of supply |
---|
Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |