The stainless steel AirLoc PRGI Jacmount® Adjustable Levelers are permanently attached to the levelling stud by means of a patented lock and yet are flexible enough that uneven flooors up to 4° can be levelled. Ideally suited to the food and chemical industries. The economical, stainless steel AirLoc GLRI Jacmount® Adjustable Levelers are used when vibration and structure-borne noise isolation is required for machines that have suitable fastening holes in the machine foot.

 TypeArt. no.Max. load
[daN]
Diameter
D [mm]
Height
H [mm]
Bottom pad 
Type illustrationGLRI 50 /4101.19111.452005117410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypeGLRI 50 /410
NameJacmounts INOX 1.4301
Art. no.1.19111.45
Technical Data
Max. load [daN]200
Weight [kg]0.114
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]17
Height Hmin [mm] M1027
Height Hmin [mm] M1229.5
Height Hmin [mm] M1633
Diameter D [mm]51
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM10, M12, M16more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 50 /9101.19111.754005117910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypeGLRI 50 /910
NameJacmounts INOX 1.4301
Art. no.1.19111.75
Technical Data
Max. load [daN]400
Weight [kg]0.132
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]17
Height Hmin [mm] M1027
Height Hmin [mm] M1229.5
Height Hmin [mm] M1633
Diameter D [mm]51
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM10, M12, M16more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 50 /7101.19111.914005117710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypeGLRI 50 /710
NameJacmounts INOX 1.4301
Art. no.1.19111.91
Technical Data
Max. load [daN]400
Weight [kg]0.126
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]17
Height Hmin [mm] M1027
Height Hmin [mm] M1229.5
Height Hmin [mm] M1633
Diameter D [mm]51
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM10, M12, M16more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 70 /4101.19112.454507617410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypeGLRI 70 /410
NameJacmounts INOX 1.4301
Art. no.1.19112.45
Technical Data
Max. load [daN]450
Weight [kg]0.29
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]17
Height Hmin [mm] M1230
Height Hmin [mm] M1633
Height Hmin [mm] M2036
Diameter D [mm]76
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM12, M16, M20more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 70 /9101.19112.7510007617910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypeGLRI 70 /910
NameJacmounts INOX 1.4301
Art. no.1.19112.75
Technical Data
Max. load [daN]1000
Weight [kg]0.286
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]17
Height Hmin [mm] M1230
Height Hmin [mm] M1633
Height Hmin [mm] M2036
Diameter D [mm]76
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM12, M16, M20more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 70 /7101.19112.919007617710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypeGLRI 70 /710
NameJacmounts INOX 1.4301
Art. no.1.19112.91
Technical Data
Max. load [daN]900
Weight [kg]0.288
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]17
Height Hmin [mm] M1230
Height Hmin [mm] M1633
Height Hmin [mm] M2036
Diameter D [mm]76
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM12, M16, M20more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationGLRI 100 /4101.19114.4590010719410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypeGLRI 100 /410
NameJacmounts INOX 1.4301
Art. no.1.19114.45
Technical Data
Max. load [daN]900
Weight [kg]0.685
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]19
Height Hmin [mm] M1635
Height Hmin [mm] M2038
Height Hmin [mm] M2442
Diameter D [mm]107
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationGLRI 100 /9101.19114.75200010719910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypeGLRI 100 /910
NameJacmounts INOX 1.4301
Art. no.1.19114.75
Technical Data
Max. load [daN]2000
Weight [kg]0.722
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]19
Height Hmin [mm] M1635
Height Hmin [mm] M2038
Height Hmin [mm] M2442
Diameter D [mm]107
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationGLRI 100 /7101.19114.91175010719710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypeGLRI 100 /710
NameJacmounts INOX 1.4301
Art. no.1.19114.91
Technical Data
Max. load [daN]1750
Weight [kg]0.698
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]19
Height Hmin [mm] M1635
Height Hmin [mm] M2038
Height Hmin [mm] M2442
Diameter D [mm]107
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 120 /4101.19116.45130013221410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypeGLRI 120 /410
NameJacmounts INOX 1.4301
Art. no.1.19116.45
Technical Data
Max. load [daN]1300
Weight [kg]1.3
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]21
Height Hmin [mm] M1637
Height Hmin [mm] M2040
Height Hmin [mm] M2444
Diameter D [mm]132
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 120 /9101.19116.75300013221910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypeGLRI 120 /910
NameJacmounts INOX 1.4301
Art. no.1.19116.75
Technical Data
Max. load [daN]3000
Weight [kg]1.3
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]21
Height Hmin [mm] M1637
Height Hmin [mm] M2040
Height Hmin [mm] M2444
Diameter D [mm]132
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationGLRI 120 /7101.19116.91275013221710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypeGLRI 120 /710
NameJacmounts INOX 1.4301
Art. no.1.19116.91
Technical Data
Max. load [daN]2750
Weight [kg]1.294
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]21
Height Hmin [mm] M1637
Height Hmin [mm] M2040
Height Hmin [mm] M2444
Diameter D [mm]132
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Studs type S INOXStuds type S INOXM16, M20, M24more
Useful remarks
On request available in 1.4435.
Remark extent of supply
Studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 50 /4101.19141.451755119410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypePRGI 50 /410
NameJacmounts pat. INOX 1.4301
Art. no.1.19141.45
Technical Data
Max. load [daN]175
Weight [kg]0.152
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]19
Height Hmin [mm] M1043
Height Hmin [mm] M1245.5
Height Hmin [mm] M1653.5
Diameter D [mm]51
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G1 INOXSpecial studs G1 INOXM10, M12, M16more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 50 /9101.19141.754005119910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypePRGI 50 /910
NameJacmounts pat. INOX 1.4301
Art. no.1.19141.75
Technical Data
Max. load [daN]400
Weight [kg]0.157
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]19
Height Hmin [mm] M1043
Height Hmin [mm] M1245.5
Height Hmin [mm] M1653.5
Diameter D [mm]51
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G1 INOXSpecial studs G1 INOXM10, M12, M16more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 50 /7101.19141.913505119710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypePRGI 50 /710
NameJacmounts pat. INOX 1.4301
Art. no.1.19141.91
Technical Data
Max. load [daN]350
Weight [kg]0.148
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]19
Height Hmin [mm] M1043
Height Hmin [mm] M1245.5
Height Hmin [mm] M1653.5
Diameter D [mm]51
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]20
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G1 INOXSpecial studs G1 INOXM10, M12, M16more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 70 /4101.19142.454007622410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypePRGI 70 /410
NameJacmounts pat. INOX 1.4301
Art. no.1.19142.45
Technical Data
Max. load [daN]400
Weight [kg]0.444
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]76
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 70 /9101.19142.7510007622910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypePRGI 70 /910
NameJacmounts pat. INOX 1.4301
Art. no.1.19142.75
Technical Data
Max. load [daN]1000
Weight [kg]0.453
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]76
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 70 /7101.19142.918007622710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypePRGI 70 /710
NameJacmounts pat. INOX 1.4301
Art. no.1.19142.91
Technical Data
Max. load [daN]800
Weight [kg]0.444
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]76
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]45
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationPRGI 100 /4101.19144.4590010722410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypePRGI 100 /410
NameJacmounts pat. INOX 1.4301
Art. no.1.19144.45
Technical Data
Max. load [daN]900
Weight [kg]0.845
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]107
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationPRGI 100 /9101.19144.75200010722910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypePRGI 100 /910
NameJacmounts pat. INOX 1.4301
Art. no.1.19144.75
Technical Data
Max. load [daN]2000
Weight [kg]0.89
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]107
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Article illustrationPRGI 100 /7101.19144.91175010722710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypePRGI 100 /710
NameJacmounts pat. INOX 1.4301
Art. no.1.19144.91
Technical Data
Max. load [daN]1750
Weight [kg]0.89
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]107
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]90
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Article illustration

Article illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 120 /4101.19146.45130013222410
Article information
Passive placement of sensitive devices and machine placement in multi storied buildings. Best vibration isolation despite low installation height.
TypePRGI 120 /410
NameJacmounts pat. INOX 1.4301
Art. no.1.19146.45
Technical Data
Max. load [daN]1300
Weight [kg]1.35
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]132
Pad equipment
Bottom pad type410
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.9
Hardness [° Shore A]40 - 45
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 120 /9101.19146.75300013222910
Article information
For transport lines and special machines. Excellent constant leveling stability and overall stability.
TypePRGI 120 /910
NameJacmounts pat. INOX 1.4301
Art. no.1.19146.75
Technical Data
Max. load [daN]3000
Weight [kg]1.36
Temperature range from [°C]-20
Temperature range to [°C]80
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]132
Pad equipment
Bottom pad type910
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]90 - 95
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch
Type illustrationPRGI 120 /7101.19146.91250013222710
Article information
For tool, production, plastic and textile machines. Superior isolation and damping properties. Excellent non-skid properties.
TypePRGI 120 /710
NameJacmounts pat. INOX 1.4301
Art. no.1.19146.91
Technical Data
Max. load [daN]2500
Weight [kg]1.342
Temperature range from [°C]-15
Temperature range to [°C]100
Dimensions
Height H [mm]22
Height Hmin [mm] M1654.5
Height Hmin [mm] M2060.5
Height Hmin [mm] M2471
Diameter D [mm]132
Pad equipment
Bottom pad type710
Pad thickness unloaded [mm]10
Coefficient of friction on concrete with fine mortar0.8
Hardness [° Shore A]70 - 75
Bottom pad area A1 [cm2]133
Suitable studs, special studs, leveling screws, leveling sockets
Special studs G2 INOXSpecial studs G2 INOXM16, M20, M24more
Useful remarks
The body of the element and the special levelling stud are, once installed, connected with each other, forming one single unit. The special levelling stud is exchangeable at any time by means of a patented connection. On request available in 1.4435.
Remark extent of supply
Special studs need to be ordered separately.

Type illustration

Type illustration

Dimensioned sketch

Dimensioned sketch
Dimensioned sketch top view

Mounting sketch

Mounting sketch

Our application engineers will be glad to recommend you the optimum solution. Please contact us!

To top

© 2024 AirLoc Ltd.Telephone: +41 44 929 77 00
Industriestrasse 2, CH-8618 Oetwil am See
www.airloc.com
contact(at)airloc.com
Technical changes without prior notice
Print date: 04.12.2024