| Type | Art. no. | Max. load [daN] | Length L [mm] | Width B [mm] | Height H [mm] | Bottom pad | |
---|
 | 212-VRC /716 + N9 | 1.32212.56 | 2500 | 115 | 115 | 56 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 212-VRC /716 + N9 | Name | Wedgmounts | Art. no. | 1.32212.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 2500 | Leveling range [mm] | 4 | Leveling range [mm] | -5 | Leveling distance per turn [mm] | 0.25 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 2.789 |
Dimensions |
---|
Height H [mm] | 56 | Height HoB in neutral position, without pads [mm] | 41 | Length L [mm] | 115 | Length L1 [mm] | 50 | Length L2 [mm] | 18.5 | Length Lmax [mm] | 185 | x [mm] | 58 | y [mm] | 27 | Width B [mm] | 115 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 19 | Width across flats SW2 [mm] | 10 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 123 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 212-VRC /716 + N9 | 1.32212.56 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Article illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 212-VRC /902 + N9 | 1.32212.59 | 4000 | 115 | 115 | 43 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 212-VRC /902 + N9 | Name | Wedgmounts | Art. no. | 1.32212.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 4000 | Leveling range [mm] | 4 | Leveling range [mm] | -5 | Leveling distance per turn [mm] | 0.25 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 2.65 |
Dimensions |
---|
Height H [mm] | 43 | Height HoB in neutral position, without pads [mm] | 41 | Length L [mm] | 115 | Length L1 [mm] | 50 | Length L2 [mm] | 18.5 | Length Lmax [mm] | 185 | x [mm] | 58 | y [mm] | 27 | Width B [mm] | 115 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 19 | Width across flats SW2 [mm] | 10 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 123 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 212-VRC /902 + N9 | 1.32212.59 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Article illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 212-VRC /915 + N9 | 1.32212.65 | 4000 | 115 | 115 | 56 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 212-VRC /915 + N9 | Name | Wedgmounts | Art. no. | 1.32212.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 4000 | Leveling range [mm] | 4 | Leveling range [mm] | -5 | Leveling distance per turn [mm] | 0.25 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 2.81 |
Dimensions |
---|
Height H [mm] | 56 | Height HoB in neutral position, without pads [mm] | 41 | Length L [mm] | 115 | Length L1 [mm] | 50 | Length L2 [mm] | 18.5 | Length Lmax [mm] | 185 | x [mm] | 58 | y [mm] | 27 | Width B [mm] | 115 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 19 | Width across flats SW2 [mm] | 10 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 123 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 212-VRC /915 + N9 | 1.32212.65 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Article illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 213-VRC /716 + N9 | 1.32213.56 | 3500 | 140 | 140 | 61 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 213-VRC /716 + N9 | Name | Wedgmounts | Art. no. | 1.32213.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 3500 | Leveling range [mm] | 6 | Leveling range [mm] | -6 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 4.75 |
Dimensions |
---|
Height H [mm] | 61 | Height HoB in neutral position, without pads [mm] | 46 | Length L [mm] | 140 | Length L1 [mm] | 51 | Length L2 [mm] | 30 | Length Lmax [mm] | 219 | x [mm] | 70 | y [mm] | 27 | Width B [mm] | 140 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 190 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 213-VRC /716 + N9 | 1.32213.56 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 213-VRC /902 + N9 | 1.32213.59 | 6000 | 140 | 140 | 48 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 213-VRC /902 + N9 | Name | Wedgmounts | Art. no. | 1.32213.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 6000 | Leveling range [mm] | 6 | Leveling range [mm] | -6 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 4.5 |
Dimensions |
---|
Height H [mm] | 48 | Height HoB in neutral position, without pads [mm] | 46 | Length L [mm] | 140 | Length L1 [mm] | 51 | Length L2 [mm] | 30 | Length Lmax [mm] | 219 | x [mm] | 70 | y [mm] | 27 | Width B [mm] | 140 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 190 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 213-VRC /902 + N9 | 1.32213.59 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 213-VRC /915 + N9 | 1.32213.65 | 6000 | 140 | 140 | 61 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 213-VRC /915 + N9 | Name | Wedgmounts | Art. no. | 1.32213.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 6000 | Leveling range [mm] | 6 | Leveling range [mm] | -6 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 4.75 |
Dimensions |
---|
Height H [mm] | 61 | Height HoB in neutral position, without pads [mm] | 46 | Length L [mm] | 140 | Length L1 [mm] | 51 | Length L2 [mm] | 30 | Length Lmax [mm] | 219 | x [mm] | 70 | y [mm] | 27 | Width B [mm] | 140 | Inner diameter d1 [mm] | 22 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 190 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 213-VRC /915 + N9 | 1.32213.65 | 1 |  | Washers with protect. cap | N | 9.20060 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 214-VRC /716 + G9 | 1.32214.56 | 5000 | 170 | 170 | 68 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 214-VRC /716 + G9 | Name | Wedgmounts | Art. no. | 1.32214.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 5000 | Leveling range [mm] | 5 | Leveling range [mm] | -8 | Leveling distance per turn [mm] | 0.28 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 7.5 |
Dimensions |
---|
Height H [mm] | 68 | Height HoB in neutral position, without pads [mm] | 53 | Length L [mm] | 170 | Length L1 [mm] | 61 | Length L2 [mm] | 28 | Length Lmax [mm] | 257 | x [mm] | 68 | y [mm] | 27 | Width B [mm] | 170 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 275 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 214-VRC /716 + G9 | 1.32214.56 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 214-VRC /902 + G9 | 1.32214.59 | 8000 | 170 | 170 | 55 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 214-VRC /902 + G9 | Name | Wedgmounts | Art. no. | 1.32214.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 8000 | Leveling range [mm] | 5 | Leveling range [mm] | -8 | Leveling distance per turn [mm] | 0.28 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 7.1 |
Dimensions |
---|
Height H [mm] | 55 | Height HoB in neutral position, without pads [mm] | 53 | Length L [mm] | 170 | Length L1 [mm] | 61 | Length L2 [mm] | 28 | Length Lmax [mm] | 257 | x [mm] | 68 | y [mm] | 27 | Width B [mm] | 170 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 275 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 214-VRC /902 + G9 | 1.32214.59 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 214-VRC /915 + G9 | 1.32214.65 | 8000 | 170 | 170 | 68 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 214-VRC /915 + G9 | Name | Wedgmounts | Art. no. | 1.32214.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 8000 | Leveling range [mm] | 5 | Leveling range [mm] | -8 | Leveling distance per turn [mm] | 0.28 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 7.5 |
Dimensions |
---|
Height H [mm] | 68 | Height HoB in neutral position, without pads [mm] | 53 | Length L [mm] | 170 | Length L1 [mm] | 61 | Length L2 [mm] | 28 | Length Lmax [mm] | 257 | x [mm] | 68 | y [mm] | 27 | Width B [mm] | 170 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 22 | Width across flats SW2 [mm] | 12 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 275 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 214-VRC /915 + G9 | 1.32214.65 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 215-VRC /716 + G9 | 1.32215.56 | 8000 | 180 | 230 | 77 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 215-VRC /716 + G9 | Name | Wedgmounts | Art. no. | 1.32215.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 8000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 12.5 |
Dimensions |
---|
Height H [mm] | 77 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 180 | Length L1 [mm] | 81 | Length L2 [mm] | 46 | Length Lmax [mm] | 307 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 215-VRC /716 + G9 | 1.32215.56 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 215-VRC /902 + G9 | 1.32215.59 | 10000 | 180 | 230 | 64 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 215-VRC /902 + G9 | Name | Wedgmounts | Art. no. | 1.32215.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 10000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 11.713 |
Dimensions |
---|
Height H [mm] | 64 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 180 | Length L1 [mm] | 81 | Length L2 [mm] | 46 | Length Lmax [mm] | 307 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 215-VRC /902 + G9 | 1.32215.59 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 215-VRC /915 + G9 | 1.32215.65 | 10000 | 180 | 230 | 77 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 215-VRC /915 + G9 | Name | Wedgmounts | Art. no. | 1.32215.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 10000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 12.444 |
Dimensions |
---|
Height H [mm] | 77 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 180 | Length L1 [mm] | 81 | Length L2 [mm] | 46 | Length Lmax [mm] | 307 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 215-VRC /915 + G9 | 1.32215.65 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 216-VRC /716 + G9 | 1.32216.56 | 8000 | 205 | 230 | 77 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 216-VRC /716 + G9 | Name | Wedgmounts | Art. no. | 1.32216.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 8000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 13.384 |
Dimensions |
---|
Height H [mm] | 77 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 205 | Length L1 [mm] | 87 | Length L2 [mm] | 46 | Length Lmax [mm] | 338 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 216-VRC /716 + G9 | 1.32216.56 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 216-VRC /902 + G9 | 1.32216.59 | 12000 | 205 | 230 | 64 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 216-VRC /902 + G9 | Name | Wedgmounts | Art. no. | 1.32216.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 12000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 12.713 |
Dimensions |
---|
Height H [mm] | 64 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 205 | Length L1 [mm] | 87 | Length L2 [mm] | 46 | Length Lmax [mm] | 338 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 216-VRC /902 + G9 | 1.32216.59 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 216-VRC /915 + G9 | 1.32216.65 | 12000 | 205 | 230 | 77 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 216-VRC /915 + G9 | Name | Wedgmounts | Art. no. | 1.32216.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 12000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.3 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 13.45 |
Dimensions |
---|
Height H [mm] | 77 | Height HoB in neutral position, without pads [mm] | 62 | Length L [mm] | 205 | Length L1 [mm] | 87 | Length L2 [mm] | 46 | Length Lmax [mm] | 338 | x [mm] | 90 | y [mm] | 27 | Width B [mm] | 230 | Inner diameter d1 [mm] | 26 | Width across flats SW1 [mm] | 30 | Width across flats SW2 [mm] | 17 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 402 |
AccessoriesProduct contentsName | Type | Art. no. | Quantity |
---|
 | Wedgmounts | 216-VRC /915 + G9 | 1.32216.65 | 1 |  | Washers with protect. cap | G | 9.20070 | 1 |
Remark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 407.2-VRC /716 | 1.32407.56 | 10000 | 250 | 200 | 80 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 407.2-VRC /716 | Name | Wedgmounts | Art. no. | 1.32407.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 10000 | Leveling range [mm] | 11 | Leveling range [mm] | -10 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 16.175 |
Dimensions |
---|
Height H [mm] | 80 | Height HoB in neutral position, without pads [mm] | 65 | Length L [mm] | 250 | Length L1 [mm] | 83 | Length L2 [mm] | 73 | Length Lmax [mm] | 414 | x [mm] | 125 | y [mm] | 32 | Width B [mm] | 200 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 27 | Width across flats SW2 [mm] | 14 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 500 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 407.2-VRC /902 | 1.32407.59 | 22500 | 250 | 200 | 67 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 407.2-VRC /902 | Name | Wedgmounts | Art. no. | 1.32407.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 22500 | Leveling range [mm] | 11 | Leveling range [mm] | -10 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 15.75 |
Dimensions |
---|
Height H [mm] | 67 | Height HoB in neutral position, without pads [mm] | 65 | Length L [mm] | 250 | Length L1 [mm] | 83 | Length L2 [mm] | 73 | Length Lmax [mm] | 414 | x [mm] | 125 | y [mm] | 32 | Width B [mm] | 200 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 27 | Width across flats SW2 [mm] | 14 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 500 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 407.2-VRC /915 | 1.32407.65 | 22500 | 250 | 200 | 80 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 407.2-VRC /915 | Name | Wedgmounts | Art. no. | 1.32407.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 22500 | Leveling range [mm] | 11 | Leveling range [mm] | -10 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 16.35 |
Dimensions |
---|
Height H [mm] | 80 | Height HoB in neutral position, without pads [mm] | 65 | Length L [mm] | 250 | Length L1 [mm] | 83 | Length L2 [mm] | 73 | Length Lmax [mm] | 414 | x [mm] | 125 | y [mm] | 32 | Width B [mm] | 200 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 27 | Width across flats SW2 [mm] | 14 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 500 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 414.2-VRC /716 | 1.32414.56 | 15000 | 300 | 250 | 99 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 414.2-VRC /716 | Name | Wedgmounts | Art. no. | 1.32414.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 15000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 32.463 |
Dimensions |
---|
Height H [mm] | 99 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 41 | Width B [mm] | 250 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 750 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 414.2-VRC /902 | 1.32414.59 | 30000 | 300 | 250 | 86 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 414.2-VRC /902 | Name | Wedgmounts | Art. no. | 1.32414.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 30000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 31.21 |
Dimensions |
---|
Height H [mm] | 86 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 41 | Width B [mm] | 250 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 750 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 414.2-VRC /915 | 1.32414.65 | 30000 | 300 | 250 | 99 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 414.2-VRC /915 | Name | Wedgmounts | Art. no. | 1.32414.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 30000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 32.575 |
Dimensions |
---|
Height H [mm] | 99 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 41 | Width B [mm] | 250 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 750 |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 450.2-VRC /716 | 1.32450.56 | 25000 | 300 | 400 | 99 | 716 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For tool, plastic, graphic and general production machines. Superior isolation and damping properties. Excellent non-skid properties. | Type | 450.2-VRC /716 | Name | Wedgmounts | Art. no. | 1.32450.56 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 25000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 | Weight [kg] | 54.713 |
Dimensions |
---|
Height H [mm] | 99 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 42 | Width B [mm] | 400 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 716 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.85 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 1186 |
Suitable studs |
---|
 | Studs RGM | M24 | more |  | Studs S | M24 | more |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 450.2-VRC /902 | 1.32450.59 | 50000 | 300 | 400 | 86 | 902 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For lathes, grinding machines, boring machines, transport lines and special machines. Ideal stability and non-skid properties. Without vibration isolation.
| Type | 450.2-VRC /902 | Name | Wedgmounts | Art. no. | 1.32450.59 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 50000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 52.732 |
Dimensions |
---|
Height H [mm] | 86 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 42 | Width B [mm] | 400 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 902 | Pad thickness unloaded [mm] | 2 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 1186 |
Suitable studs |
---|
 | Studs RGM | M24 | more |  | Studs S | M24 | more |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |
 | 450.2-VRC /915 | 1.32450.65 | 50000 | 300 | 400 | 99 | 915 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For transport lines, special machines and tool machines. High load capacity, excellent constant leveling stability and overall stability. | Type | 450.2-VRC /915 | Name | Wedgmounts | Art. no. | 1.32450.65 | Color | RAL 7016 anthracite grey | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [daN] | 50000 | Leveling range [mm] | 9 | Leveling range [mm] | -9 | Leveling distance per turn [mm] | 0.23 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 | Weight [kg] | 54.891 |
Dimensions |
---|
Height H [mm] | 99 | Height HoB in neutral position, without pads [mm] | 84 | Length L [mm] | 300 | Length L1 [mm] | 117 | Length L2 [mm] | 79 | Length Lmax [mm] | 497 | x [mm] | 143 | y [mm] | 42 | Width B [mm] | 400 | Inner diameter d1 [mm] | 28 | Width across flats SW1 [mm] | 36 |
Pad equipment |
---|
Bottom pad type | 915 | Pad thickness unloaded [mm] | 15 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 1186 |
Suitable studs |
---|
 | Studs RGM | M24 | more |  | Studs S | M24 | more |
AccessoriesRemark extent of supply |
---|
Studs need to be ordered separately. |
Type illustrationSystem descriptionDimensioned sketchMounting sketch |