CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight systems and laboratory instruments which require a very high level of effective isolation. | | Type | PR 50 /B1 | | Name | Jacmounts | | Art. no. | 1.13050-9005.50 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 230 | | Weight [kg] | 0.037 | | Temperature range from [°C] | -20 | | Temperature range to [°C] | 80 |
| Dimensions |
|---|
| Height H [mm] | 23.5 | | Height Hmin [mm] M10 | 31.5 | | Height Hmin [mm] M12 | 32.5 | | Diameter D [mm] | 57 |
| Pad equipment |
|---|
| Bottom pad type | B1 | | Pad thickness unloaded [mm] | 13 | | Coefficient of friction on concrete with fine mortar | 0.9 | | Hardness [° Shore A] | 40 - 45 | | Bottom pad area A1 [cm2] | 20 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-1 | M10, M12 for threaded machine foot | more |  | Special studs O-1-S | M10, M12 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight machines and systems requiring superior leveling stability and very good overall stability. | | Type | PR 50 /910 | | Name | Jacmounts | | Art. no. | 1.13050-9005.75 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 230 | | Weight [kg] | 0.035 | | Temperature range from [°C] | -20 | | Temperature range to [°C] | 80 |
| Dimensions |
|---|
| Height H [mm] | 20.5 | | Height Hmin [mm] M10 | 28.5 | | Height Hmin [mm] M12 | 29.5 | | Diameter D [mm] | 57 |
| Pad equipment |
|---|
| Bottom pad type | 910 | | Pad thickness unloaded [mm] | 10 | | Coefficient of friction on concrete with fine mortar | 0.8 | | Hardness [° Shore A] | 90 - 95 | | Bottom pad area A1 [cm2] | 20 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-1 | M10, M12 for threaded machine foot | more |  | Special studs O-1-S | M10, M12 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight machines which demand excellent damping properties. | | Type | PR 50 /710 | | Name | Jacmounts | | Art. no. | 1.13050-9005.91 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 230 | | Weight [kg] | 0.034 | | Temperature range from [°C] | -15 | | Temperature range to [°C] | 100 |
| Dimensions |
|---|
| Height H [mm] | 20.5 | | Height Hmin [mm] M10 | 28.5 | | Height Hmin [mm] M12 | 29.5 | | Diameter D [mm] | 57 |
| Pad equipment |
|---|
| Bottom pad type | 710 | | Pad thickness unloaded [mm] | 10 | | Coefficient of friction on concrete with fine mortar | 0.8 | | Hardness [° Shore A] | 70 - 75 | | Bottom pad area A1 [cm2] | 20 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-1 | M10, M12 for threaded machine foot | more |  | Special studs O-1-S | M10, M12 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight systems and laboratory instruments which require a very high level of effective isolation. | | Type | PR 75-2 /B1 | | Name | Jacmounts | | Art. no. | 1.13076-9005.50 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 500 | | Weight [kg] | 0.086 | | Temperature range from [°C] | -20 | | Temperature range to [°C] | 80 |
| Dimensions |
|---|
| Height H [mm] | 28 | | Height Hmin [mm] M10 | 36 | | Height Hmin [mm] M12 | 37 | | Height Hmin [mm] M16 | 39.5 | | Diameter D [mm] | 82 |
| Pad equipment |
|---|
| Bottom pad type | B1 | | Pad thickness unloaded [mm] | 13 | | Coefficient of friction on concrete with fine mortar | 0.9 | | Hardness [° Shore A] | 40 - 45 | | Bottom pad area A1 [cm2] | 44 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-2 | M10, M12, M16, M20, M24 for threaded machine foot | more |  | Special studs O-2-S | M10, M12, M16 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight machines and systems requiring superior leveling stability and very good overall stability. | | Type | PR 75-2 /910 | | Name | Jacmounts | | Art. no. | 1.13076-9005.75 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 1100 | | Weight [kg] | 0.086 | | Temperature range from [°C] | -20 | | Temperature range to [°C] | 80 |
| Dimensions |
|---|
| Height H [mm] | 25 | | Height Hmin [mm] M10 | 33 | | Height Hmin [mm] M12 | 34 | | Height Hmin [mm] M16 | 36.5 | | Diameter D [mm] | 82 |
| Pad equipment |
|---|
| Bottom pad type | 910 | | Pad thickness unloaded [mm] | 10 | | Coefficient of friction on concrete with fine mortar | 0.8 | | Hardness [° Shore A] | 90 - 95 | | Bottom pad area A1 [cm2] | 44 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-2 | M10, M12, M16, M20, M24 for threaded machine foot | more |  | Special studs O-2-S | M10, M12, M16 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
CONTACT
CALL-BACK
QUOTATION
| Article information |
|---|
| For light-weight machines which demand excellent damping properties. | | Type | PR 75-2 /710 | | Name | Jacmounts | | Art. no. | 1.13076-9005.91 | | Color | RAL 9005 jet black |
| Technical Data |
|---|
| Max. load [lbs] | 1100 | | Weight [kg] | 0.082 | | Temperature range from [°C] | -15 | | Temperature range to [°C] | 100 |
| Dimensions |
|---|
| Height H [mm] | 25 | | Height Hmin [mm] M10 | 33 | | Height Hmin [mm] M12 | 34 | | Height Hmin [mm] M16 | 36.5 | | Diameter D [mm] | 82 |
| Pad equipment |
|---|
| Bottom pad type | 710 | | Pad thickness unloaded [mm] | 10 | | Coefficient of friction on concrete with fine mortar | 0.8 | | Hardness [° Shore A] | 70 - 75 | | Bottom pad area A1 [cm2] | 44 |
| Suitable studs, special studs, leveling screws, leveling sockets |
|---|
 | Special studs U-2 | M10, M12, M16, M20, M24 for threaded machine foot | more |  | Special studs O-2-S | M10, M12, M16 for machine foot with bore | more |
| Remark extent of supply |
|---|
| Special studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |