| Type | Art. no. | Max. load [lbs] | Diameter D [mm] | Height Hmin [mm] | Bottom pad | |
---|
| PRP 90-M12/425 | 1.15091.48 | 900 | 101 | 50 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 90-M12/425 | Name | Jacmounts M12x1.5 | Art. no. | 1.15091.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 900 | Leveling range [mm] | 20 | Weight [kg] | 0.883 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 101 | inner thread d1 | M12x1.5 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 54 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M12x1.5 | more | | Levelling studs R2 | M12x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 90-M12/925 | 1.15091.64 | 3400 | 101 | 50 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 90-M12/925 | Name | Jacmounts M12x1.5 | Art. no. | 1.15091.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 3400 | Leveling range [mm] | 20 | Weight [kg] | 0.95 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 101 | inner thread d1 | M12x1.5 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 54 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M12x1.5 | more | | Levelling studs R2 | M12x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 90-M12/725 | 1.15091.68 | 2200 | 101 | 50 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 90-M12/725 | Name | Jacmounts M12x1.5 | Art. no. | 1.15091.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 2200 | Leveling range [mm] | 20 | Weight [kg] | 0.95 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 101 | inner thread d1 | M12x1.5 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 54 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M12x1.5 | more | | Levelling studs R2 | M12x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 120 /425 | 1.15120.48 | 1300 | 123 | 50 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 120 /425 | Name | Jacmounts M16x1.5 | Art. no. | 1.15120.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 1300 | Leveling range [mm] | 25 | Weight [kg] | 1.65 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 123 | inner thread d1 | M16x1.5 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 74 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M16x1.5 | more | | Levelling studs R2 | M16x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 120 /925 | 1.15120.64 | 4500 | 123 | 50 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 120 /925 | Name | Jacmounts M16x1.5 | Art. no. | 1.15120.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 4500 | Leveling range [mm] | 25 | Weight [kg] | 1.65 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 123 | inner thread d1 | M16x1.5 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 74 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M16x1.5 | more | | Levelling studs R2 | M16x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 120 /725 | 1.15120.68 | 3400 | 123 | 50 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 120 /725 | Name | Jacmounts M16x1.5 | Art. no. | 1.15120.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 3400 | Leveling range [mm] | 25 | Weight [kg] | 1.64 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 50 | Diameter D [mm] | 123 | inner thread d1 | M16x1.5 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 74 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M16x1.5 | more | | Levelling studs R2 | M16x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 160 /425 | 1.15160.48 | 2700 | 168 | 52 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 160 /425 | Name | Jacmounts M20x1.5 | Art. no. | 1.15160.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 2700 | Leveling range [mm] | 25 | Weight [kg] | 2.95 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 52 | Diameter D [mm] | 168 | inner thread d1 | M20x1.5 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 157 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M20x1.5 | more | | Levelling studs R2 | M20x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 160 /925 | 1.15160.64 | 8000 | 168 | 52 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 160 /925 | Name | Jacmounts M20x1.5 | Art. no. | 1.15160.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 8000 | Leveling range [mm] | 25 | Weight [kg] | 3.1 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 52 | Diameter D [mm] | 168 | inner thread d1 | M20x1.5 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 157 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M20x1.5 | more | | Levelling studs R2 | M20x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 160 /725 | 1.15160.68 | 6750 | 168 | 52 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 160 /725 | Name | Jacmounts M20x1.5 | Art. no. | 1.15160.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 6750 | Leveling range [mm] | 25 | Weight [kg] | 3.0 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 52 | Diameter D [mm] | 168 | inner thread d1 | M20x1.5 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 157 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M20x1.5 | more | | Levelling studs R2 | M20x1.5 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 200 /425 | 1.15200.48 | 4000 | 205 | 54 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 200 /425 | Name | Jacmounts M24x2 | Art. no. | 1.15200.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 4000 | Leveling range [mm] | 25 | Weight [kg] | 4.75 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 54 | Diameter D [mm] | 205 | inner thread d1 | M24x2 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 241 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M24x2 | more | | Levelling studs R2 | M24x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRP 200 /925 | 1.15200.64 | 9000 | 205 | 54 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 200 /925 | Name | Jacmounts M24x2 | Art. no. | 1.15200.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 9000 | Leveling range [mm] | 25 | Weight [kg] | 4.8 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 54 | Diameter D [mm] | 205 | inner thread d1 | M24x2 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 241 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M24x2 | more | | Levelling studs R2 | M24x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRP 200 /725 | 1.15200.68 | 9000 | 205 | 54 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 200 /725 | Name | Jacmounts M24x2 | Art. no. | 1.15200.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 9000 | Leveling range [mm] | 25 | Weight [kg] | 4.7 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 54 | Diameter D [mm] | 205 | inner thread d1 | M24x2 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 241 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M24x2 | more | | Levelling studs R2 | M24x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Article illustrationDimensioned sketchMounting sketch |
| PRP 250-HD /425 | 1.15253.48 | 6750 | 260 | 60 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 250-HD /425 | Name | Jacmounts M27x2 | Art. no. | 1.15253.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 6750 | Leveling range [mm] | 25 | Weight [kg] | 11.184 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 60 | Diameter D [mm] | 260 | inner thread d1 | M27x2 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 408 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M27x2 | more | | Levelling studs R2 | M27x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 250-HD /925 | 1.15253.64 | 18000 | 260 | 60 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 250-HD /925 | Name | Jacmounts M27x2 | Art. no. | 1.15253.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 18000 | Leveling range [mm] | 25 | Weight [kg] | 11.25 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 60 | Diameter D [mm] | 260 | inner thread d1 | M27x2 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 408 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M27x2 | more | | Levelling studs R2 | M27x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 250-HD /725 | 1.15253.68 | 18000 | 260 | 60 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 250-HD /725 | Name | Jacmounts M27x2 | Art. no. | 1.15253.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 18000 | Leveling range [mm] | 25 | Weight [kg] | 11.243 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 60 | Diameter D [mm] | 260 | inner thread d1 | M27x2 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 408 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M27x2 | more | | Levelling studs R2 | M27x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 300-HD /425 | 1.15302.48 | 10000 | 305 | 73 | 425 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For nibbling machines and compressors. Best isolation effect, high stability and good damping. | Type | PRP 300-HD /425 | Name | Jacmounts M30x2 | Art. no. | 1.15302.48 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 10000 | Leveling range [mm] | 25 | Weight [kg] | 17.439 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 73 | Diameter D [mm] | 305 | inner thread d1 | M30x2 |
Pad equipment |
---|
Bottom pad type | 425 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.9 | Hardness [° Shore A] | 40 - 45 | Bottom pad area A1 [cm2] | 638 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M30x2 | more | | Levelling studs R2 | M30x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 300-HD /925 | 1.15302.64 | 22000 | 305 | 73 | 925 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines, machines with high dynamic horizontcal force, Extremely high degree of horizontal stability. | Type | PRP 300-HD /925 | Name | Jacmounts M30x2 | Art. no. | 1.15302.64 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 22000 | Leveling range [mm] | 25 | Weight [kg] | 17.45 | Temperature range from [°C] | -20 | Temperature range to [°C] | 80 |
Dimensions |
---|
Height Hmin [mm] | 73 | Diameter D [mm] | 305 | inner thread d1 | M30x2 |
Pad equipment |
---|
Bottom pad type | 925 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 90 - 95 | Bottom pad area A1 [cm2] | 638 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M30x2 | more | | Levelling studs R2 | M30x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |
| PRP 300-HD /725 | 1.15302.68 | 22000 | 305 | 73 | 725 | |
CONTACT
CALL-BACK
QUOTATION
Article information |
---|
For injection moulding machines and machines with high dynamic vertical force. Fast and effective movement damping. | Type | PRP 300-HD /725 | Name | Jacmounts M30x2 | Art. no. | 1.15302.68 | Color | RAL 1018 zinc yellow | Other colors upon request. | Surface treatment | painted |
Technical Data |
---|
Max. load [lbs] | 22000 | Leveling range [mm] | 25 | Weight [kg] | 17.5 | Temperature range from [°C] | -15 | Temperature range to [°C] | 100 |
Dimensions |
---|
Height Hmin [mm] | 73 | Diameter D [mm] | 305 | inner thread d1 | M30x2 |
Pad equipment |
---|
Bottom pad type | 725 | Pad thickness unloaded [mm] | 25 | Coefficient of friction on concrete with fine mortar | 0.8 | Hardness [° Shore A] | 70 - 75 | Bottom pad area A1 [cm2] | 638 |
Suitable studs, special studs, leveling screws, leveling sockets |
---|
| Levelling studs R1 | M30x2 | more | | Levelling studs R2 | M30x2 | more |
Remark extent of supply |
---|
Levelling studs need to be ordered separately. |
Type illustrationDimensioned sketchMounting sketch |